HVAC and air changes per hour
-
max
- Posts: 6
- Joined: Tue Oct 19, 2004 3:25 pm
- Location: Melbourne, Australia
HVAC and air changes per hour
Hello all,
I was hoping somebody could point me in the right direction with this HVAC concern.
I'm building a recording studio in Melbourne, Australia. It will run as a business so it must comply with safety standards, however I'm having trouble finding out how many air changes per hour I need in my otherwise airtight (hopefully) performance room.
The performance room dimensions are 4860mm length X 3120mm width X 2440mm height, which gives me a cubic capacity of 37m.
I'd think that things in the room that generate heat and consume oxygen would have to be factored into this query. There would be no more than eight people in there at any given time, and no more than six speaker cabinets (though usually a lot less).
I'm not installing air conditioning as the place stays cool during summer. My main concern is:
At what rate should fresh air be pumping into the room?
At what rate should carbon monoxide/stale air be pumped out of the room?
Any help would be greatly appreciated.
Max Anceschi
I was hoping somebody could point me in the right direction with this HVAC concern.
I'm building a recording studio in Melbourne, Australia. It will run as a business so it must comply with safety standards, however I'm having trouble finding out how many air changes per hour I need in my otherwise airtight (hopefully) performance room.
The performance room dimensions are 4860mm length X 3120mm width X 2440mm height, which gives me a cubic capacity of 37m.
I'd think that things in the room that generate heat and consume oxygen would have to be factored into this query. There would be no more than eight people in there at any given time, and no more than six speaker cabinets (though usually a lot less).
I'm not installing air conditioning as the place stays cool during summer. My main concern is:
At what rate should fresh air be pumping into the room?
At what rate should carbon monoxide/stale air be pumped out of the room?
Any help would be greatly appreciated.
Max Anceschi
-
sharward
- Moderator
- Posts: 4281
- Joined: Mon Jan 03, 2005 4:08 pm
- Location: Sacramento, Northern California, USA
- Contact:
The answer is different depending on your township. Here in the states, we have many model codes, with different release dates, so two cities next door to each other could have different (albeit similar) requirements.
Your best bet is to determine what codes are in effect in your township and consult with the building department there.
At least, that's how we do it over here.
Hope that helps...
--Keith
Your best bet is to determine what codes are in effect in your township and consult with the building department there.
At least, that's how we do it over here.
Hope that helps...
--Keith
-
WiseMindsRecordingStudios
- Posts: 121
- Joined: Mon Sep 05, 2005 11:39 am
- Location: Elmira, New York
- Contact:
-
sharward
- Moderator
- Posts: 4281
- Joined: Mon Jan 03, 2005 4:08 pm
- Location: Sacramento, Northern California, USA
- Contact:
-
knightfly
- Senior Member
- Posts: 6976
- Joined: Sun Mar 16, 2003 11:11 am
- Location: West Coast, USA
Hopefully, that's the UN-scented Co2 we're talking about...
Here's a basic guideline, barring any interference from local "BRA's"
http://www.warmair.com/html/air_to_air_exchangers.htm
And more -
http://www.nibs.org/BETEC/Fall00.PDF
HTH... Steve
Here's a basic guideline, barring any interference from local "BRA's"
http://www.warmair.com/html/air_to_air_exchangers.htm
And more -
http://www.nibs.org/BETEC/Fall00.PDF
HTH... Steve
Soooo, when a Musician dies, do they hear the white noise at the end of the tunnel??!? Hmmmm...
-
sharward
- Moderator
- Posts: 4281
- Joined: Mon Jan 03, 2005 4:08 pm
- Location: Sacramento, Northern California, USA
- Contact:
That page contains the following statement above the calculator:knightfly wrote:Here's a basic guideline, barring any interference from local "BRA's"
http://www.warmair.com/html/air_to_air_exchangers.htm
- "A properly sized Air Exchanger will completely replace the air inside your house a total of 6 times per day."
-
knightfly
- Senior Member
- Posts: 6976
- Joined: Sun Mar 16, 2003 11:11 am
- Location: West Coast, USA
Yeah, noticed that; IIRC the other link was better on that. Most stuff I've seen wants 2-3 changes per hour. I think maybe that 6 per day thing was more of an "extra" for a house or something; no code I've seen is that lax, although there does seem to be quite a range depending on usage of the space... Steve
Soooo, when a Musician dies, do they hear the white noise at the end of the tunnel??!? Hmmmm...
-
sharward
- Moderator
- Posts: 4281
- Joined: Mon Jan 03, 2005 4:08 pm
- Location: Sacramento, Northern California, USA
- Contact:
-
sharward
- Moderator
- Posts: 4281
- Joined: Mon Jan 03, 2005 4:08 pm
- Location: Sacramento, Northern California, USA
- Contact:
Yes, "extra" for a house with windows. For living space that has no windows, code requires something a bit short of a DC-9 jet engine to move the air in and out.knightfly wrote:I think maybe that 6 per day thing was more of an "extra" for a house or something . . .